Industrial antomation prduct:

PLC,DCS,Sensor,Inverter,encoder,relay,Servo Drives,Soft,starter,touch,screen

Work hard and best service for you!

Sales & Support
Request A Quote - Email
Select Language
English
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsIndustrial Servo Motor

R88M-G1K520T-B-Z 1500W Power Industrial Two Phase AC Servo Motor

R88M-G1K520T-B-Z 1500W Power Industrial Two Phase AC Servo Motor

R88M-G1K520T-B-Z 1500W Power Industrial Two Phase AC Servo Motor
R88M-G1K520T-B-Z 1500W Power Industrial Two Phase AC Servo Motor R88M-G1K520T-B-Z 1500W Power Industrial Two Phase AC Servo Motor

Large Image :  R88M-G1K520T-B-Z 1500W Power Industrial Two Phase AC Servo Motor Get Best Price

Product Details:

Place of Origin: Japan
Brand Name: OMRON
Certification: CE
Model Number: R88M-G1K520T-B-Z

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Contact us
Packaging Details: New in original box
Delivery Time: 5-8DAYS
Payment Terms: T/T, , L/C
Supply Ability: 88
Detailed Product Description
Warranty: 12 Months Condition: New And Original
Quality: New And Original Type: Two Phase Ac Servo Motor

Brand: OMRON Model: R88M-G1K520T-B-Z
Origion: Japan
High Light:

ac servo motor

,

electric servo motor

 

 

1500W R88M-G1K520T-B-Z OMRON AC Servo Motor the current consumption of other controllers

 

Maximum Input Current:


The Servo Drive's maximum momentary output is approximately three times the rated output, and
can be output for up to three seconds.
Therefore, select no-fuse breakers with an operating time of at least five seconds at 300% of the
rated current. General-purpose and low-speed no-fuse breakers are generally suitable.
Select a no-fuse-breaker with a rated current greater than the total effective load current of all the
Servomotors. The rated current of the power supply input for each Servomotor is provided in Main
Circuit and Servomotor Connector Specifications .
Add the current consumption of other controllers, and any other components, when selecting the
NFB.

 

 

Inrush Current:


The following table lists the Servo Drive inrush currents.
With low-speed no-fuse breakers, an inrush current 10 times the rated current can flow for
0.02 second.
When multiple Servo Drives are turned ON simultaneously, select a no-fuse-breaker with a 20-ms
allowable current that is greater than the total inrush current, shown in the following table.

Leakage Breakers


Select leakage breakers designed for protection against grounding faults.
Because switching takes place inside the Servo Drives, high-frequency current leaks from the
switching elements of the Servo Drive, the armature of the motor, and the cables.
High-frequency breakers with surge withstand capability do not detect high-frequency current,
preventing the breaker from operating with high-frequency leakage current.
When using a general-purpose leakage breaker, use three times the sum of the leakage current
given in the following table as a reference value.
When selecting leakage breakers, remember to add the leakage current from devices other than
the Servomotor, such as machines using a switching power supply, noise filters, inverters, and so
on. To prevent malfunction due to inrush current, we recommend using a leakage breaker of ten
times the total of all current values.
The leakage breaker is activated at 50% of the rated current. Allow leeway when selecting a
leakage breaker.
For details on leakage breakers, refer to the manufacturer’s catalog.
The following table shows the Servomotor leakage current for each Servo Drive model.

 

Surge Absorbers


Use surge absorbers to absorb lightning surge voltage and abnormal voltage from power supply
input lines.
When selecting surge absorbers, take into account the varistor voltage, the allowable surge
current and the energy.
For 200-VAC systems, use surge absorbers with a varistor voltage of 620 V.
The surge absorbers shown in the following table are recommended.

 

AC Servo Drives

Linear Motor with built-in EtherCAT communications

 

Specifications Model
Power Model Supply Voltage Applicable Servomotor Capacity
Single-phase
100 VAC
100 W R88D-KN01L-ECT-L
200 W R88D-KN02L-ECT-L
400 W R88D-KN04L-ECT-L
Single-phase/three-phase
200 VAC
100 W R88D-KN01H-ECT-L
200 W R88D-KN02H-ECT-L
400 W R88D-KN04H-ECT-L
750 W R88D-KN08H-ECT-L
1 kW R88D-KN10H-ECT-L
1.5 kW R88D-KN15H-ECT-L
Three-phase
400 VAC
600 W R88D-KN06F-ECT-L
1 kW R88D-KN10F-ECT-L
1.5 kW R88D-KN15F-ECT-L
2 kW R88D-KN20F-ECT-L
3 kW R88D-KN30F-ECT-L

 

Linear Motors

<Iron-core motor type>

Motor Coil Unit

 

Motor Coil Unit model Continuous force [N] Momentary maximum force [N]
R88L-EC-FW-0303-ANPC 48 105
R88L-EC-FW-0306-ANPC 96 210
R88L-EC-FW-0606-ANPC 160 400
R88L-EC-FW-0609-ANPC 240 600
R88L-EC-FW-0612-ANPC 320 800
R88L-EC-FW-1112-ANPC 608 1600
R88L-EC-FW-1115-ANPC 760 2000

 

Magnet Trac

 

Magnet Trac model Magnet Trac Unit Length (mm)
R88L-EC-FM-03096-A 96
R88L-EC-FM-03144-A 144
R88L-EC-FM-03384-A 384
R88L-EC-FM-06192-A 192
R88L-EC-FM-06288-A 288
R88L-EC-FM-11192-A 192
R88L-EC-FM-11288-A 288

 

 

1500W R88M-G1K520T-B-Z OMRON AC Servo Motor the current consumption of other controllers 0

 

 
 

 

 

Contact person: Iris
E-mail: Iriss88@163.com
Cellphone: +0086-17728602038
Fixed line:0752-2222038