Industrial Electric Yaskawa 3000RPM AC Servo Motor 750W 200V SGMP-08A3TE12
Specifications
Brand Name Yaskawa
Model Number SGMP-08A3TE12
Place of Origin Japan
Power 750W
Volatage 200V
Current 4.1A
R/MIN 3000RPM
INS B
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG-
Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X-
Emerson VE-,KJ-
Honeywell TC-,TK-
GE Modules IC -
Fanuc motor A0-
Yokogawa transmitter EJA-
SIMILAR PRODUCTS
SGMP-01A312
SGMP01A312 SERVO MOTOR
yaskawa
SGMP-01A314
SGMP01A314 SERVO MOTOR
yaskawa
SGMP-01A314B
SGMP01A314B SERVO MOTOR
yaskawa
SGMP-01A316
SGMP01A316 SERVO MOTOR
yaskawa
SGMP-01A3SI21
SGMP01A3SI21 SERVO MOTOR
yaskawa
SGMP-01A3SI31
SGMP01A3SI31 SERVO MOTOR
yaskawa
SGMP-01A3SI41
SGMP01A3SI41 SERVO MOTOR
yaskawa
SGMP-01A3TE11
SGMP01A3TE11 SERVO MOTOR
yaskawa
SGMP-01A8YR11
SGMP01A8YR11 SERVO MOTOR
yaskawa
SGMP-01AW12
SGMP01AW12 SERVO MOTOR
yaskawa
SGMP-01AW12B
SGMP01AW12B SERVO MOTOR
yaskawa
SGMP-01AWA4SPU
SGMP01AWA4SPU SERVO MOTOR
yaskawa
SGMP-01AWR12
SGMP01AWR12 SERVO MOTOR
yaskawa
SGMP-01AWYR12
SGMP01AWYR12 AC W/BRAKE 0.89A/ 200V/100W
yaskawa
SGMP-01AWYR22
SGMP01AWYR22 CUBE 0.13HP 200V EN STANDARD
yaskawa
SGMP-01B312
SGMP01B312 SERVO MOTOR
yaskawa
SGMP-01B314
SGMP01B314 SERVO MOTOR
yaskawa
SGMP-01B316B
SGMP01B316B SERVO MOTOR
yaskawa
SGMP-01B5SW11
SGMP01B5SW11 SERVO MOTOR
yaskawa
SGMP-01B5SW21
SGMP01B5SW21 SERVO MOTOR
yaskawa
SGMP-01BW12
SGMP01BW12 SERVO MOTOR
yaskawa
SGMP-01L314M
SGMP01L314M SERVO MOTOR
yaskawa
SGMP-01U312
SGMP01U312 SERVO MOTOR
yaskawa
SGMP-01U314CM
SGMP01U314CM SERVO MOTOR
yaskawa
SGMP-01U314EM
SGMP01U314EM SERVO MOTOR
yaskawa
SGMP-01U314M
SGMP01U314M SERVO MOTOR
yaskawa
SGMP-01U3AP08
SGMP01U3AP08 SERVO MOTOR
yaskawa
Notice
Observe proper electrostatic discharge (ESD) procedures when handling the drive. Failure to comply could result in ESD damage to the drive circuitry. It may be difficult to perform maintenance on the cooling fans of drives installed in a vertical row inside an enclosure. Ensure adequate spacing at the top of the drive to perform cooling fan replacement when required. Operating the motor in the low-speed range diminishes the cooling effects, increases motor temperature, and may lead to motor damage by overheating. Reduce the motor torque in the low-speed range whenever using a standard blower cooled motor. If 100% torque is required continuously at low speed, consider using a special drive or vector motor. Select a motor that is compatible with the required load torque and operating speed range. Do not operate motors above the maximum rated RPM. Failure to comply may lead to bearing or other mechanical motor failures. The speed range for continuous operation differs according to the lubrication method and motor manufacturer. If the motor is to be operated at a speed higher than the rated speed, consult with the manufacturer. Continuously operating an oil-lubricated motor in the low-speed range may result in burning.
Environment Conditions
Installation Area Indoors
Ambient Temperature
-10 °C to +50 °C (IP20/Open-Chassis)
Drive reliability improves in environments without wide temperature fluctuations.
When using an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air temperature inside
the enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.
Humidity 95% RH or less and free of condensation
Storage Temperature -20 °C to +60 °C
Surrounding Area
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
Altitude Up to 1000 meters without derating; up to 3000 meters with output current, ambient temperature, and voltage derating.
Refer to Altitude Derating on page 186 for details.
Vibration 10 to 20 Hz at 9.8 m/s2
20 to 55 Hz at 5.9 m/s2
Orientation Install the drive vertically to maintain maximum cooling effects.
Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during installation and project construction. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary cover before startup, as the cover will reduce ventilation and cause the drive to overheat.