Industrial AC Servo Motor MSM3AZA8AX 106V 3000RPM Panasonic 0.4KW,2.5A 200Hz,116V
Quick Detail
RATED REV 3000RPM
RATED Freq 200Hz
RATED Output 0.4KW
Input 106V
Detailed Product Description
Brand
Panasonic
Country of origin
Japan
model number
MSM3AZA8AX
Product Details
Panasonic A-Series Motor
Manufacturer: Panasonic
Series: A-Series
Specifications:
Item
Specifications
Input power
100 V
Main circuit
Single phase 100 V +10 %-15 % ~120 V +10 %-15 % 50 Hz / 60 Hz
Control circuit
Single phase 100 V +10 %-15 % ~120 V +10 %-15 % 50 Hz / 60 Hz
200 V
Main circuit
A-frame to
D-frame
Single/3-phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz / 60 Hz
E-frame,
F-frame
Single/3-phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz / 60 Hz
Control
circuit
A-frame to
D-frame
Single phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz / 60 Hz
E-frame,
F-frame
Single phase 200 V +10 %-15 % ~240 V +10 %-15 % 50 Hz / 60 Hz
Environment
temperature
Ambient temperature: 0 ˚C to 55 ˚C (free from freezing)
Storage temperature: –20 ˚C to 65 ˚C
(Max.temperature guarantee: 80 ˚C for 72 hours free from condensation*1)
humidity
Both operating and storage : 20 % to 85 %RH (free from condensation*1)
Altitude
Lower than 1000 m
Vibration
5.88 m/s2 or less, 10 Hz to 60 Hz
Control method
IGBT PWM Sinusoidal wave drive
Encoder feedback
23-bit (8388608 resolution) absolute encoder, 7-wire serial
* When using the product as an incremental system (not using multi-turn data), do not connect a battery for absolute encoder. Instead, set the parameter Pr0.15 to [1] (default).
External scale feedback
A/B phase, initialization signal defferential input.
Manufacturers that support serial communication scale:
Fagor Automation S.Coop., Magnescale Co., Ltd., Mitutoyo Corporation Nidec Sankyo Corporation, Renishaw plc
Parallel I/O connector
Control signal
Input
General purpose 10 inputs
The function of general-purpose input is selected by parameters.
Output
General purpose 6 outputs
The function of general-purpose output is selected by parameters.
2 inputs (Photo-coupler input, Line receiver input)
Both open collector and line driver interface can be connected.
High speed line driver interface can be connected.
Output
4 outputs ( Line driver: 3 output, open collector: 1 output)
Line driver output for encoder pulses (A/B/Z signal) or external feedback pulses (EXA/EXB/EXZ signal) open collector output also available for Z or EXZ signal.
Communication
function
USB
USB interface to connect to computers for parameter setting or status monitoring.
RS232
1:1 communication
RS485
1: n communication (max 31)
Safety function
A dedicated connector is provided for Functional Safety.
Front panel
(1) 5 keys
(2) LED (6-digit)
Regeneration
A-frame, B,-frame: no built-in regenerative resistor (external resistor only)
C-frame to F-frame: Built-in regenerative resistor (external resistor is also enabled.)
Dynamic brake
A-frame to F-frame: Built-in
Control mode
Switching among the following 7 mode is enabled,
(1) Position control
(2) Speed control
(3) Toque control
(4) Position/Speed control
(5) Position/Torque control
(6) Speed/Torque control
(7) Full-closed control
Item
Specifications
Control input
(1) servo-ON input
(2) Alarm clear input
(3) Gain switch input
(4) Positive direction drive inhibit input
(5) Negative direction drive inhibit input
(6) Forced alarm input
(7) Inertia ratio switch input
Control output
(1) Servo-alarm output
(2) Servo-ready output
(3) External brake off output
(4) At-speed output
(5) Torque in-limit output
(6) Zero speed detection output
(7) Warning output
(8) Alarm clear attribute output
(9) Servo on status output
(1) In-position output
(2) Position command ON/OFF output
Pulse
input
Max. command pulse frequency
500 kpps (Optocoupler interface), 8 Mpps (When using line receiver input multiplied by 4)
Input pulse signal format
Differential input. Selectable by parameter.
([1]Positive/Negative pulse [2]A/B quadrature [3]Pulse/Direction)
Electronic gear
(Division/Multiplication of
command pulse)
Applicable scaling ratio: 1/1000 times to 8000 times
Any value of 1 - 2 30 can be set for both numerator (which corresponds to encoder resolution) and denominator (which corresponds to command pulse resolution per motor revolution), but the combination has to be within the range shown above.
Smoothing filter
Primary delay filter or FIR type filter is adaptable to the command input
Analog
input
Torque limit command input
Individual torque limit for both positive and negative direction is enabled.
Torque feed forward input
Analog voltage can be used as torque feed forward input.
Velocity command input with analog voltage is possible. Scale setting and command polarity vary depending on parameters. (6 V/Rated rotational speed: Default)
Torque limit command input
Individual torque limit for both positive and negative direction is enabled.
Torque feed forward input
Analog voltage can be used as torque feed forward input.
Internal velocity command
Switching the internal 8 speed is enabled by command input.
Soft-start/down function
Individual setup of acceleration and deceleration is enabled, with 0 s to 10 s/ 1000 r/min. Sigmoid acceleration/deceleration is also enabled.
Speed zero clamp
Internal velocity command can be clamped to 0 with speed zero clamp input.
Two-degree-of-freedom control
Available
Torque control
Control input
Speed zero clamp input, torque command sign input, control mode switch input.
(1) In-position output
(2) Position command ON/OFF output
Pulse
input
Max. command pulse frequency
500 kpps (Optocoupler interface), 8 Mpps (When using line receiver input multiplied by 4)
Input pulse signal format
Differential input. Selectable by parameter.
([1]Positive/Negative pulse [2]A/B quadrature [3]Pulse/Direction)
Electronic gear
(Division/Multiplication of
command pulse)
Applicable scaling ratio: 1/1000 times to 8000 times
Any value of 1 - 2 30 can be set for both numerator (which corresponds to encoder resolution) and denominator (which corresponds to command pulse resolution per motor revolution), but the combination has to be within the range shown above.
Smoothing filter
Primary delay filter or FIR type filter is adaptable to the command input
Analog
input
Torque limit command input
Individual torque limit for both positive and negative direction is enabled.
Torque feed forward input
Analog voltage can be used as torque feed forward input.
Setting range of external scale
division/multiplication
1/40 times to 1280 times
Although ratio of the encoder pulse (numerator) and external scale pulse (denominator) can be arbitrarily set in the range of 1 to 2 23 for the numerator and in the range of 1 to 2 23 for the denominator, this product should be used within the aforementioned range.
Two-degree-of-freedom control
Available
Anti-vibration control
Available
Common
Auto tuning
The load inertia is identified in real time by the driving state of the motor operating according to the command given by the controlling device and set up support software “PANATERM”. The gain is set automatically in accordance with the rigidity setting.
Division of encoder feedback pulse
Set up of any value is enabled (encoder pulses count is the max.).
Protective function
Hard error
Over-voltage, under-voltage, over-speed, over-load, over-heat, over-current and
encoder error etc.
Soft error
Excess position deviation, command pulse division error, EEPROM error etc.
Alarm data trace back
Tracing back of alarm data is available
The following are some of the drive models, both new and used are stocked: