Large Image :  SGD-01BP Yaskawa Servo Drives 115w Power Max Output AC Servopack Get Best Price

Product Details:

Place of Origin: Japan
Brand Name: Yasakawa
Certification: CE
Model Number: SGD-01BP

Payment & Shipping Terms:

Minimum Order Quantity: 1 pc
Price: Contact us
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, , L/C
Supply Ability: 88
Detailed Product Description
Package: Original Package Color: Black/Red/White/Grey
Quality: New And Original Material: Sperial Materials
Product Name: Yaskawa Ac Servopack

rand: Yasakawa Model: SGD-01BP
Palce Of Origin: Japan Type: Servopack
Output AMPS: 4.5 Input Volatge: 200-230v
Input Frequency: 50/60hz Input PH: 1
High Light:

electric servo drive

,

ac servo pack

 

 

YASKAWA Industrial 100 Watt SERVO DRIVE Input 100-115V 2.2AMPS 50/60hz SGD-01BP

 

 

 

 

Quick Details

Brand Name:Yaskawa
Model Number:SGD-01BP
Input Voltage:100-115V
Input Frequency:50/60HZ
Input PH : 1
Input AMPS:4.5
Series : Sigma 2 (Σ-II Series)
Output Power : 100W
Output Voltage: 0-115V
Output AMPS:2.2
Output PH :3
Temperture: 0-55℃
Place of Origin:Japan
Efficiency:IE 1

 

 

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- Fanuc motor A0-
Rosemount transmitter 3051- Yokogawa transmitter EJA-
 
 
 
 
 
 
Similar Products
SGD-01AN+SGM-01A3NT14
SGD-01AHY130
SGD-01AS
SGD-01BH
SGD-01BP
SGD-02AH
SGD-02AHY500
SGD-02AN
SGD-02ANY6
SGD-02AP
SGD-02AS
SGD-02BH
SGD-02BP
SGD-02BS+SGM-02B312
SGD-02BS+SGM-02B314
SGD-04AN
SGD-04AN+SGM-04A3NT12
SGD-04AP
SGD-04APY61
SGD-04AS
SGD-04ASY52
SGD-04ASY53
SGD-08AH
SGD-08AN
SGD-08AP
SGD-08APY61
SGD-08ASY25

 

 

 

 

 

YASKAWA Industrial 100 Watt SERVO DRIVE Input 100-115V   2.2AMPS 50/60hz SGD-01BP 0

 

 

 

Electrical Shock Hazard

Do not operate equipment with covers removed. Failure to comply could result in death or serious injury. The diagrams in this section may show drives without covers or safety shields to show details. Be sure to reinstall covers or shields before operating the drives and run the drives according to the instructions described in this manual. Always ground the motor-side grounding terminal. Improper equipment grounding could result in death or serious injury by contacting the motor case.

Do not perform work on the drive while wearing loose clothing, jewelry or without eye protection. Failure to comply could result in death or serious injury. Remove all metal objects such as watches and rings, secure loose clothing, and wear eye protection before beginning work on the drive.

Do not remove covers or touch circuit boards while the power is on. Failure to comply could result in death or serious injury.

Do not allow unqualified personnel to perform work on the drive. Failure to comply could result in death or serious injury. Installation, maintenance, inspection, and servicing must be performed only by authorized personnel familiar with installation, adjustment, and maintenance of AC drives.

Do not touch any terminals before the capacitors have fully discharged. Failure to comply could result in death or serious injury. Before wiring terminals, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least one minute after all indicators are off and measure the DC bus voltage level to confirm safe level. Fire Hazard Tighten all terminal screws to the specified tightening torque. Loose electrical connections could result in death or serious injury by fire due to overheating of electrical connections. Do not use improper combustible materials. Failure to comply could result in death or serious injury by fire. Attach the drive to metal or other noncombustible material

.Do not use an improper voltage source. Failure to comply could result in death or serious injury by fire. Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power

 

 

 

Terminals Terminal
Screws Tightening
Torque lb-in (N•m)
Possible Wire Sizes
AWG (mm2)
Recommended Wire Size AWG (mm2)
Wire Type
S1, S2, S3, S4, S5, S6, S7
SN, SC, SP, +V, A1, A2,
AC, MI, M2, M3, M4,
MA, MB, MC, FM, AC,
AM, R+, R-, S+, S-, IG
Phoenix type *3
4.2 to 5.3 (0.5 to 0.6)
Stranded wire: 26 to 16
(0.14 to 1.5) 18
(0.75) • Shielded, twisted-pair wire*1
• Shielded, polyethylene-covered,
vinyl sheath cable
E(G) M3.5 7.0 to 8.8
(0.8 to 1.0) 20 to 14
(0.5 to 2*2) 12 n(1.25)
*1. Use shielded twisted-pair cables to input an external speed command.
*2. Yaskawa recommends using straight solderless terminals on digital inputs to simplify wiring and improve reliability.
*3. Yaskawa recommends using a thin-slot screwdriver with a 3.5 mm blade width.

 
 
 