Product Details:
Payment & Shipping Terms:
|
Package: | Original Package | Color: | Black/Red/White/Grey |
---|---|---|---|
Quality: | New And Original | Function: | Testing Mechanical Resonance Point |
AC Servo Motor SGMSS-10ACA21 NEW YASKAWA ELECTRIC Made in Japan 3000 1/min
QUICK DETAILS
DESCRIPTION
SEPCIFICATIONS
Brand Name | Yaskawa |
Model Number | SGMSS-10ACA21 |
Place of Origin | Japan |
Current | 5.7A |
Voltage | 200V |
Speed | 3000 1/min |
Power | 1000W |
Ins | F |
The flexible cable supports 10,000,000 or more operations of bending life with the recommended bending radius R = 90 mm (3.54 in) under the following test conditions. • Conditions
1. Repeat moving one end of the cable forward and backward for 320 mm (12.60 in) using the test equipment shown in the following.
2. Connect the lead wires in parallel, and count the number of cable return motion times until a lead wire is disconnected. Note that one reciprocation is counted as one test.
NOTE
1. The life of flexible cable differs largely depending on the amount of mechanical shocks, mounting to the cable, and fixing methods. The life of flexible cable is limited under the specified conditions.
2. The life of flexible cable indicates the number of bending times in which lead wires are electrically conducted and by which no cracks and damages that affects the performance of cable sheathing are caused. Disconnecting the shield wire is not taken into account.
Overview
SynqNet™ is a synchronous network technology designed for multi-axis motion control applications. The physical layer of SynqNet is based on the physical layer of Ethernet. SynqNet operates over two pairs of wires, one pair for 'receive' data signals and the other pair for 'transmit' data signals. Each receiving node uses digital timecorrection techniques to minimize skew and jitter. Service channel capability is used to query nodes or servo for drive parameters and status information.
SynqNet defines cable shielding conventions in order to properly isolate local node signals and power while minimizing EMI (both emission and reception). Shielded cabling will reduce EMI coupled from other devices in the system. The cables shall have their shields connected to the metal connector shell using the clamp on the MicroD connector. Cable shield connections are treated slightly differently at the controller and node PCBs. Both are detailed below.
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Contact person: Iris
E-mail: Iriss88@163.com
Cellphone: +0086-17728602038
Fixed line:0752-2222038
Contact Person: Miss. Iris
Tel: 86-17728602038